JMD Association for Molecular Pathology 2008 Annual Meeting
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH

A more recent version of this article appeared on July 1, 2007

Published online before print April 26, 2007
This Article
Right arrow Full Text (Rapid PDF)
Right arrow All Versions of this Article:
jmoldx.2007.070017v1
9/3/394    most recent
Right arrow Purchase Article
Right arrow View Shopping Cart
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schrijver, I.
Right arrow Articles by Zehnder, J. L.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Schrijver, I.
Right arrow Articles by Zehnder, J. L.
Copyright © 2007 American Society for Investigative Pathology
Journal of Molecular Diagnostics, doi:10.2353/jmoldx.2007.070017


Accepted for publication February 23, 2007.


Regular Articles

Testing for Maternal Cell Contamination in Prenatal Samples. A Comprehensive Survey of Current Diagnostic Practices in 35 Molecular Diagnostic Laboratories

Iris Schrijver*@, Sarah C. Cherny{dagger}, and James L. Zehnder{dagger}

From the Departments of Pathology and Pediatrics* and Pathology,{dagger} Stanford University School of Medicine, Stanford, California

@ To whom correspondence should be addressed. E-mail: ischrijver{at}stanfordmed.org.


   Abstract

The potential presence of maternal cell contamination (MCC) in chorionic villus or amniotic fluid samples poses a serious preanalytical risk for prenatal misdiagnosis. The aim of this study was to identify current diagnostic practices in the absence of comprehensive practice guidelines. Thirty-five clinical molecular laboratories that conduct prenatal testing agreed to participate in a clinical practice survey. The survey included questions about sample requirements, test indications, assay type, test performance and limitations, criteria and management of uninformative test results, reporting, and billing. Sixty percent of participating laboratories performed testing on direct and cultured amniotic fluid, whereas forty percent tested cultured cells only. Most also accepted chorionic villus samples. Although MCC testing of fetal samples is recommended in guidelines by the American College of Medical Genetics, only 60% of surveyed laboratories performed it without exception. Commercially available assays were used by 75% of participating laboratories, and at least five identity markers were evaluated at 87% of the laboratories. The reported lower limit of MCC detection ranged from 1 to 20% but was not determined in all laboratories. MCC testing was performed in the majority of molecular diagnostic laboratories, but guidelines for standardization are needed to ensure optimal and accurate prenatal patient care.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Copyright © 2007 by the American Society for Investigative Pathology and the Association for Molecular Pathology.