| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Published online before print April 26, 2007
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Technical Advance |






From the ARUP Institute for Clinical and Experimental Pathology
* and ARUP Laboratories,
Salt Lake City; and the Department of Pathology,
University of Utah Medical School, Salt Lake City, Utah
Abstract
Amplicon melting is a closed-tube method for genotyping that does not require probes, real-time analysis, or allele-specific polymerase chain reaction. However, correct differentiation of homozygous mutant and wild-type samples by melting temperature (Tm) requires high-resolution melting and closely controlled reaction conditions. When three different DNA extraction methods were used to isolate DNA from whole blood, amplicon Tm differences of 0.03 to 0.39°C attributable to the extractions were observed. To correct for solution chemistry differences between samples, complementary unlabeled oligonucleotides were included as internal temperature controls to shift and scale the temperature axis of derivative melting plots. This adjustment was applied to a duplex amplicon melting assay for the methylenetetrahydrofolate reductase variants 1298A>C and 677C>T. High- and low-temperature controls bracketing the amplicon melting region decreased the Tm SD within homozygous genotypes by 47 to 82%. The amplicon melting assay was 100% concordant to an adjacent hybridization probe (HybProbe) melting assay when temperature controls were included, whereas a 3% error rate was observed without temperature correction. In conclusion, internal temperature controls increase the accuracy of genotyping by high-resolution amplicon melting and should also improve results on lower resolution instruments.
This article has been cited by other articles:
![]() |
C. N. Gundry, S. F. Dobrowolski, Y. R. Martin, T. C. Robbins, L. M. Nay, N. Boyd, T. Coyne, M. D. Wall, C. T. Wittwer, and D. H.-F. Teng Base-pair neutral homozygotes can be discriminated by calibrated high-resolution melting of small amplicons Nucleic Acids Res., June 1, 2008; 36(10): 3401 - 3408. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. R. L. Teo, W. Wang, H. Yang Law, C. G. Lee, and S. S. Chong Single-Step Scalable-Throughput Molecular Screening for Huntington Disease Clin. Chem., June 1, 2008; 54(6): 964 - 972. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. De Leeneer, I. Coene, B. Poppe, A. De Paepe, and K. Claes Rapid and Sensitive Detection of BRCA1/2 Mutations in a Diagnostic Setting: Comparison of Two High-Resolution Melting Platforms Clin. Chem., June 1, 2008; 54(6): 982 - 989. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Y. Cai, P. Bell-Rogers, L. Parker, A. Ferencz, and P. Pozder Development and field validation of a Mycoplasma iowae real-time polymerase chain reaction assay J Vet Diagn Invest, March 1, 2008; 20(2): 230 - 235. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. L. Margraf, R. Mao, and C. T. Wittwer Rapid Diagnosis of MEN2B Using Unlabeled Probe Melting Analysis and the LightCycler 480 Instrument J. Mol. Diagn., March 1, 2008; 10(2): 123 - 128. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. T. Seipp, D. Pattison, J. D. Durtschi, M. Jama, K. V. Voelkerding, and C. T. Wittwer Quadruplex Genotyping of F5, F2, and MTHFR Variants in a Single Closed Tube by High-Resolution Amplicon Melting Clin. Chem., January 1, 2008; 54(1): 108 - 115. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. G. Herrmann, J. D. Durtschi, C. T. Wittwer, and K. V. Voelkerding Expanded Instrument Comparison of Amplicon DNA Melting Analysis for Mutation Scanning and Genotyping Clin. Chem., August 1, 2007; 53(8): 1544 - 1548. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |