JMD ASIP MEMBERSHIP
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Originally published online as doi:10.2353/jmoldx.2008.070108 on February 14, 2008

Published online before print February 14, 2008
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
jmoldx.2008.070108v1
10/2/147    most recent
Right arrow Purchase Article
Right arrow View Shopping Cart
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Forman, M. S.
Right arrow Articles by Valsamakis, A.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Forman, M. S.
Right arrow Articles by Valsamakis, A.
Journal of Molecular Diagnostics 2008, Vol. 10, No. 2
Copyright © 2008 American Society for Investigative Pathology & Association for Molecular Pathology
DOI: 10.2353/jmoldx.2008.070108

Performance Characteristics of a Quantitative Hepatitis C Virus RNA Assay Using COBAS AmpliPrep Total Nucleic Acid Isolation and COBAS TaqMan Hepatitis C Virus Analyte-Specific Reagent

Michael S. Forman and Alexandra Valsamakis

From the Department of Pathology, The Johns Hopkins Medical Institutions, Baltimore, Maryland

Performance characteristics of a hepatitis C virus (HCV) RNA quantification assay comprised automated specimen extraction [COBAS AmpliPrep (CAP) using total nucleic acid isolation reagents (TNAI)], and real-time polymerase chain reaction [COBAS TaqMan 48 HCV with analyte-specific reagents (CTM48)] were determined. CAP TNAI/CTM48 performed linearly from approximately 2.0 to at least 6.7 log10 IU/ml for HCV genotypes (Gts) 1, 2, and 3. The limit of detection for the World Health Organization International Standard was 23 IU/ml. Variabilities ranged from 1.3 to 2.1%. Excellent quantitative agreement was observed in clinical samples using CTM48 and two different methods for HCV RNA extraction (CAP TNAI and BioRobot M48; regression line slope, 0.98; y-intercept, 0.11; R2, 0.98; mean difference, 0.003). Good agreement was also observed between CAP TNAI/CTM48 and COBAS Amplicor Monitor (regression line slope, 0.94; y-intercept, 0.08; R2, 0.96), although HCV RNA concentrations were on average greater by COBAS Amplicor Monitor (mean difference –0.27 log10 IU/ml). Better overall agreement was observed for Gt 1 than non-Gt 1 specimens when comparing extraction and quantification methods; however, no consistent genotype-dependent quantification bias was observed. These data suggest that CAP TNAI/CTM48 offers an alternative method for the quantification of HCV in plasma samples.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the American Society for Investigative Pathology and the Association for Molecular Pathology.