We have previously described3 a stool-based screening test for early detection of colorectal cancers. The multi-target nucleic acid assay consists of a panel of 21 specific mutations in adenomatous polyposis coli (APC),4 p53 5, 6 , and K-ras7 genes, a microsatellite instability marker (BAT-26),8 and a marker for genomic integrity (DNA Integrity assay; DIA).9 As reported in separate studies, 3, 10, 11, 12 the multi-target assay has an aggregate sensitivity of 67% (95% CI: 60.3 to 73.9%) and specificity of 97% (95% CI: 92.9 to 99.2%), a major improvement to the current screening methods of the fecal occult blood test (25 to 40% sensitivity).13, 14 In the multi-target assay studies human DNA was recovered and purified using streptavidin-bound magnetic beads.3, 15 We have reported on the use of separate components of this multi-target test elsewhere.9, 11, 16, 17, 18 The mutation panel portion of the multi-target assay relies on detecting mutations in several well-documented colorectal cancer-associated genes.19, 20 The DNA integrity portion of the test consists of a set of markers that serve as surrogate markers for the presence of long DNA fragments. The principles and performance of this portion of the test has recently been reported.9
During development of the assay we observed that the sensitivity of a gene or genome-based test is limited not only by the fact that not all colorectal tumors have identified mutations, but also by the quantity of tumor-derived DNA that can be retrieved from stool. Robust and reproducible recovery of sufficient target DNA from stool is often an unrecognized, but significant challenge for developing a population-based screening assay. The content of human DNA in stool is very small, although the total DNA that can be recovered is very high due to bacterial contribution. DNA from cells sloughed from the colonic mucosa represents as little as 0.1 to 0.01% of the total DNA recoverable from stool. Additionally, the human DNA is highly heterogenous. Tumor cells in the colon can be estimated to contribute on the order of 1% of the cells sloughed, although the amount can vary, and with early stage disease the mutant percentage can be less than 1%.21, 22
To maximize sensitivity of detecting mutant DNA for a screen of CRC in an asymptomatic population it is important to maximize the recovery of target DNA from stool. Insufficient recovery would lead to the possible absence of mutant molecules within PCR reactions, leading to false negative results, and reduced clinical sensitivity. We introduce here a novel DNA purification technology that consists of an electrophoretic driven separation of target DNA sequences, using oligonucleotide capture probes immobilized in an acrylamide gel. The amount of sample to be purified can be easily scaled to recover increasing quantities of target DNA from stool, using this approach. Using the sequence-specific electrophoretic capture method, we have demonstrated that adequate genome representation in the sample is a limiting factor for DNA-based detection of colorectal cancer and maximizing representativeness through increased recovery improves clinical sensitivity. The population of mutant sequences in the human DNA recovered from stool can be modeled by Poisson statistics. Based on a nominal 1% mutant in the human DNA, it is predicted that a minimum of 500 copies are required for high probability (99%) of detection. Likewise, for early stage disease, where the mutant population may represent less than 1% of the total human DNA recovered from stool, the minimum copies required for robust detection increases (eg, 2500 copies for 0.2% mutant DNA).
In this study a total of 186 archived stool samples were analyzed using the multi-target assay, after recovery of DNA using two different purification techniques; magnetic bead-capture and the gel-capture method. In development experiments the gel-capture approach was shown to yield increased recovery of human DNA from stool, due primarily to the ability to load more sample without overloading the sequence-specific capture layer. This study included a set of 86 archived samples from cancer patients, which had been previously analyzed.10, 11, 12 The impact of increased DNA recovery was expected to increase the detection of mutations, and clinical sensitivity, due to maximized representation of mutant sequences in PCR reactions.
| Materials and Methods |
|---|
|
|
|---|
Archived samples were stored at 80°C for an average of 12 months (range of 6 to 18 months) for use in this study. Integrity of recovered DNA was stable under these storage conditions as indicated by repeat analysis of samples.
Magnetic Bead-Based Sequence-Specific Purification15
Sequence-specific DNA fragments were purified from the total nucleic acid preparations by performing oligonucleotide-based hybrid captures. For each sample, seven unique hybrid capture reactions were performed in duplicate. Each capture reaction was carried out by adding 300 µl of sample preparation to an equal volume of 6 mol/L guanidine isothiocyanate solution (GITC), (GIBCO, Invitrogen, Carlsbad, CA) containing biotinylated sequence-specific oligonucleotides (20 pmol; Midland Certified Reagent Co., Midland, TX). The mixture was heated to 95°C, then rapidly cooled to room temperature, and after a 2-hour incubation at 25°C, the GITC was diluted to 1 mol/L concentration. Streptavidin-coated magnetic beads (Dynal, Oslo, Norway) were added to the solution, and the tubes were incubated for an additional hour at room temperature. The bead/hybrid capture complexes were then washed 4 times with 1X B&W buffer (Dynal), (1 mol/L NaCl, 0.01 mol/L Tris-HCl [pH 7.2], 0.001 mol/L EDTA, and 0.1% Tween 20), and the sequence-specific captured DNA was eluted into 35 µl TE by heat denaturation.
Acrylamide-Gel Method for DNA Purification
Target human DNA fragments were purified from total nucleic acid preparations by electrophoretically driving DNA through an affinity capture layer consisting of human, sequence-specific capture probes immobilized within an acrylamide matrix. Capture probes were synthesized as 37-mer oligonucleotides with a 5'-Acrydite23, 24
modifications (Integrated DNA Technologies, Coralville, IA). The capture probes were prepared as 1 mmol/L stock solutions in 0.1X TE buffer. The polymerization solution (1 ml total) was then prepared by mixing 119 µl acrylamide:bisacrylamide (19:1) (Roche), 20 µl of each Acrydite capture probe, 100 µl 10X Tris Borate EDTA (TBE) buffer (BioRad, Hercules, CA), 20 µl glycerol (OmniPur, Darmstadt, Germany), 22 µl dimethylformamide (Sigma), 668 µl MB-grade water (Sigma), 10 µl freshly prepared 10% Ammonium Persulfate (APS)(Sigma), and 1 µl Tetramethylethylenediamine (TEMED) (Sigma). This formulation resulted in a 5% polyacrylamide gel and 20-µmol/L concentration of capture probes. Unique mixtures were prepared for the mutation panel (consisting of a multiplexed capture of 11 unique sequences), and each of the four DIA sequences. A sheet of medical-grade polyester (SEFAR, Depew, NY), with 100-um openings, was treated with 0.5% SDS (from 10% stock, GIBCO) and dried. The sheet was then clamped between glass plates, and the polymerization mix was wicked into the sheet and allowed to polymerize for several hours. The glass plates were then separated, the gel allowed to dry, and 1-cm diameter disks were cut out. The disks were heat sealed to the bottom of a custom-molded polypropylene capture plate, consisting of 48 wells, each approximately 1 cm in diameter, and 1.5 cm in height. A matched array of 48 molded tubes was then fitted into the wells of the capture plate to accommodate up to 4 ml of sample per capture disk.
Crude human DNA preparations (2400 µl) were mixed with 960 µl formamide (Sigma), 385 µl 10X TBE, and filtered through a 0.8-um syringe filter (Nalgene, Rochester, NY), then denatured (heated at 95°C for 10 minutes, then cooled in ice for 5 minutes). First, 600 µl of 0.5% Seakem LE agarose (Cambrex, Rockland, ME) was added on top of the bonded capture membrane, and allowed to gel. The sample mix was then loaded on top of the agarose, and electrodes above and below the capture layer were applied. Samples were electrophoresed (15V, 16 hours) using TBE in the reservoirs above and below the capture layer. After electrophoretic capture the remaining solution was removed from the tubes, and the tube array (containing the agarose layer) was separated from the capture plate. The capture membranes were then washed with ST buffer (Sigma) (0.15 mol/L NaCl + 10 mmol/L Tris; pH 7.4) and the capture membranes were electrophoresed in the reverse direction (30V, 3 hours), and rinsed with ST buffer. Capture membranes were found to have sufficient porosity that captured DNA could be efficiently recovered simply using centrifugation. Therefore, 40 µl of 100 mmol/L NaOH (Sigma) was added to the top of the capture membrane and incubated for 15 minutes. The capture plate was placed on top of a custom molded 48-well DNA collection plate and centrifuged briefly (1900 x g) to recover the eluted DNA. Then, 8 µl of neutralization buffer (Sigma) (500 mmol/L HCL + 0.1X TE) was added to each well of the collection plate and mixed.
Sequence-Specific Amplification
Polymerase chain reaction (PCR) amplifications (50 µl) were performed on MJ Research Tetrad Cyclers (MJ Research, Watertown, MA) using 10 µl of purified DNA, 10X PCR buffer (Takara Bio Inc; Madison, WI), 0.2 mmol/L dNTPs (Promega, Madison, WI), 0.5 µmol/L sequence-specific primers (Midland Certified Reagent Co.), and 2.5 U LATaq DNA polymerase (Takara). All amplification reactions were performed under identical thermocycler conditions. After an initial denaturation of 94°C for 5 minutes, PCR amplification was performed for 40 cycles consisting of 1 minute at 94°C, 1 minute at 60°C, and 1 minute at 72°C, with a final extension of 5 minutes at 72°C. Thirteen separate PCR reactions were run per sample. For analysis of each of the PCR products, 8 µl of each amplification reaction was loaded and electrophoresed on a 4% ethidium bromide-stained NuSieve 3:1 agarose gel (Cambrex) and visualized with a Stratagene EagleEye II (Stratagene, La Jolla, CA) still image system. All oligonucleotide sequences [capture probes, PCR primers, and TaqMan probes] are available on request.
The multi-target assay was designed to have 13 separate PCR reactions in the multiple mutation (MuMu) panel, and 16 PCR reactions in the DIA portion of the assay. Two of the PCR reactions are overlapping for MuMu and DIA.
Mutation Panel Analysis
The presence or absence of point mutations or Bat-26-associated deletions was determined by using modified solid-phase single-base extension (SBE) reactions. Point mutation targets included; codons K12p1, K12p2, and K13p2 on the K-ras gene; codons 876, 1306, 1309, 1312, 1367p1, 1378p1, 1379, 1450p1, 1465, and 1554 on the APC gene; and codons 175p2, 245p1, 245p2, 248p1, 248p2, 273p1, 273p2, and 282p1 on the p53 gene. Including the Bat-26 deletion marker, the panel consisted of 22 markers in total. For all gene targets, separate wild-type and mutant-specific reactions were performed. The following procedure was used: PCR product (42 µl) was added to 200 µg magnetic beads (Dynal) in 40 µl of 2X B&W buffer (Dynal), and incubated at room temperature for 15 minutes. Beads were then magnetically separated, the supernatant removed, and fresh B&W buffer was added and mixed. This process was repeated twice to wash the beads, then 100 µl of 0.1N NaOH was added to dissociate the bound double-stranded PCR product. The beads were then washed with B&W buffer, and the beads were finally placed in 100 µl TE. Wild-type reactions were run with fluorescently labeled nucleotides complementary to the wild-type base added. For each of the point mutation-specific reactions, fluorescently labeled bases complementary to the expected mutant bases were added in addition to unlabeled dideoxy nucleotides complementary to the wild-type base. Specific mutant reaction mixes varied from site to site and were dependent on the expected base at the mutation site of interest (in some cases more than a single mutation is possible). All SBE reactions are 10-µl total volume. Mutant-specific reactions are prepared using 5 µl bead-bound PCR template, 1 µl 10X buffer (Perkin Elmer, Boston, MA), 1 µl SBE primer (5 µmol/L), 0.025 µl AcycloPol enzyme (32 Units/µl) (Perkin Elmer), and a mixture of unlabeled dideoxynucleotides (Promega) and R110-labeled Acycloterminators (Perkin Elmer), dependent on the specific mutant site. Acycloterminators are diluted 1:20 from the stock solution as purchased; 0.05 µl of the diluted reagent is used per mutant base. Dideoxynucleotides are first prepared as a 50-µmol/L stock solution and then 1 µl of the stock solution is added to reactions. As an example, for k12p1 (where the wild-type sequence calls for G, but A, C, and T mutations are all possible), 1 µl of the ddGTP, and 0.05 µl of the R110-A, R110-C, and R110-T Acycloterminators are added to the reaction mix). Bat-26 mutations associated with a deletion of 4 to 15 bp (bp) were identified by size discrimination of reaction products.
All samples were analyzed on an ABI 3100 capillary electrophoresis (CE) system (ABI; Foster City, CA). Labeled primer extension products were prepared for analysis on the CE, as follows. An aliquot (1 µl) of primer extension product was mixed with 9 µl of a pre-mixed formamide/ROX standard solution (190 to 6 µl, respectively). The ROX mix, which serves as a size standard, consists of 5 ROX-labeled oligonucleotides of lengths 15, 18, 25, 30, and 50 bases, dissolved in 10 mmol/L Tris-EDTA buffer. Just before analysis, mixed samples were denatured on a thermocycler at 95°C for 5 minutes, then cooled on ice for 5 minutes. Samples were analyzed on the CE using 36-cm capillary arrays (ABI) and POP-6 (ABI) in the capillaries. Run temperature was set to 60°C, the operating potential set to 15V, and samples were electrokinetically injected at 3V. Data were analyzed using the GenoTyper software package.
DNA Integrity Assay (DIA)
The DIA assay has been previously described in detail.9
More recently this assay has been converted to a real-time PCR methodology. Three unique PCR reactions (in duplicate) per loci were run on I-Cycler instruments (BioRad). The strategy was to capture locus-specific segments and perform small (
100 bp) PCR amplifications remote from the capture site as an indicator of DNA length. DNA fragments for integrity analysis were amplified from four different loci: 17p13; 5q21; HRMT1L1; LOC91199. PCR primer sets and associated TaqMan probe for each loci of interest are "walked" down the chromosome thereby interrogating for the presence and quantitation of increasing length DNA of approximately 100-bp, 1300-bp, 1800-bp, and 2400-bp fragments of captured DNA. Purified DNA template (5 µl) was mixed with 5 µl 10X PCR buffer (Takara), 10 µl dNTPs (2 mmol/L) (Promega), 0.25 µl LATaq (5 U/µl; Takara), 24.75 µl molecular biology-grade water (Sigma), 5 µl of a mix of PCR primers (5 µmol/L; Midland) and TaqMan dual-labeled probes (2 µmol/L; Biosearch Technologies, Novato, CA). The I-Cycler was programmed as follows: 94°C for 5 minutes, then 40 cycles of 94°C for 1 minute, 55°C for 1 minute, and 72°C for 1 minute. Genomic standards, prepared as 20, 100, 500, 2500, and 12500 GE/5 µl were prepared and used to generate a standard curve.
DIA Data Analysis
Threshold genome equivalents (GE) values were determined for each of 12 PCR reactions (corresponding to the 1.3-kb, 1.8-kb, and 2.4-kb fragments across the four genomic loci) using a previously determined set of cancers and normals. We then applied a requirement that at least 4 of the 12 PCR reactions are above the individual PCR thresholds to prospectively determine cancers.
Quantification of Recovered DNA by TaqMan Analysis
TaqMan analysis was performed on an I-Cycler with primers against a 200-bp region of the APC gene. A probe labeled with 6-carboxyfluorescein (FAM) and 6-carboxytetramethylrhodamine (TAMRA) was used to detect PCR product. Amplification reactions consisted of captured human stool DNA mixed with 10X PCR buffer, LATaq enzyme (Takara), 1X PCR primers (5 µmol/L), and 1X TaqMan probe (2 µmol/L; Biosearch Technologies). We used 5 µl of captured DNA in the PCR reactions. TaqMan reactions were performed with the same program as described above (DIA).
| Results |
|---|
|
|
|---|
|
|
|
|
To determine the impact of increased human DNA recovery on assay sensitivity, we analyzed the 86 cancer samples re-purified using both methods. Results are summarized in Table 2
. All of the samples (100%) that tested positive after purification with the magnetic-bead method, also tested positive (with the same markers) using the acrylamide-gel method. However, additional cancer samples were also found to be assay positive with the acrylamide-gel capture. An additional six cancer samples were detected by the mutation panel portion of the multi-target assay. In total 12 additional point mutation markers were detected, although six of these were found in samples with multiple positive markers, and therefore did not add to the clinical sensitivity of detection. Samples are all from archives (stored at 80°C) and it is possible to compare results from this analysis to the initial test results. Originally, 36 cancer samples were found to be positive for the mutation panel portion of the assay, and all of these were again confirmed to be positive with bead capture, indicating good reproducibility of the assay on repeat testing the same samples. The DIA portion of the assay reveals 19 additional cancer samples that were detected after acrylamide-gel purification, compared to bead capture. Similar to the mutation panel portion of the assay, we found 100% concordance between samples that had been found to be positive originally, and those that were positive on repeat testing.
|
|
| Discussion |
|---|
|
|
|---|
The acrylamide gel-capture method provided greater recovery of human DNA, compared to a previously developed bead-capture method when 186 stool samples were processed in parallel. The increase in DNA-recovery varied from sample to sample, and was as high as 30-fold. The average increase was 5.4-fold (P < 0.0001, by the paired t-test). The ability to capture more genome equivalents of human DNA with the acrylamide-gel method can be explained by several features of the methodology: the matrix of conjugated acrylamide has a high capacity for the human-specific capture probes such that the capture sites are not saturated by target DNA from stool; the sample is applied to the capture probes by electrophoresis, thus driving the target DNA to the capture probes in an efficient manner (bead captures by comparison rely on mass transfer via diffusion); the acrylamide matrix minimizes non-specific adsorption of non-target biomolecules, which minimizes inhibition of PCR reactions downstream. Due to these features, it is possible to readily scale-up the volume of patient sample in each capture experiment, for greater DNA yield [attempts to recover more human DNA by scaling the magnetic-bead method were unsuccessful due to PCR inhibition for an unacceptably high percentage of samples (data not shown)].
On purification and analysis of cancer samples, an increased number were detected when DNA recovery was increased, using the acrylamide-gel method. Our hypothesis is that this is due to minimized sampling error in PCR reactions when the mutant population is present in a small percentage of the total human DNA (as with fecal samples). There were three added cancer samples that were uniquely positive by the mutation panel portion of the assay. Using bead capture they were found to have recovery scores of 300, 210, and 190 GE/10 µl, respectively. Clearly all three fall below the DNA recovery target (500 GE/10 µl). When purified with the gel-capture method, these same samples gave scores of 1210, 1180, and 1630 GE/10 µl, respectively.
The majority of the increase in sensitivity was contributed by the DIA component of the multi-target assay. This result was somewhat unexpected, and the precise mechanism by which increased recovery leads to increased sensitivity is not clear at this point although we hypothesize that increased recovery of long fragments is sufficient for increased sensitivity due to the increase in template amount that leads to increased PCR efficiency.
High specificity is requisite for cost-effective screening. Four false positives were identified in this study, one due to a k-ras mutation and three to positive DIA readings. The new technique reported here for purification of human DNA from stool results in increased recovery and appears to improve the sensitivity in detecting colorectal cancer while maintaining high specificity. This should improve the robustness of the multi-target DNA assay described here as a tool for colorectal cancer screening. We also believe that other molecular techniques that rely on rare mutant detection would benefit from this recovery and purification approach.
As expected from the choice of markers, cancers at all tumor stages (Dukes A-D) were readily detected in fecal DNA analysis. No statistically significant correlation of sensitivity or specificity was observed with disease stage using either the bead-capture or the gel-capture methods. Likewise, no correlation of DNA recovery was observed with disease stage. However, we observed that there is clearly a correlation of sensitivity with recovery and that increased recovery of human DNA using the gel-capture method led to increases in sensitivity for all tumor stages. More importantly, early-stage tumors, associated with greater survival odds, are detected as readily as late-stage tumors.
|
| Acknowledgments |
|---|
| Footnotes |
|---|
Conflict of interest statement: Duncan Whitney, Joel Skoletsky, Kent Moore, Kevin Boynton, Lisa Kann, and Anthony Shuber are employees of EXACT Sciences and are all share-holders of the company. Randall Brand was formerly on EXACT Sciences Scientific Advisory Board. During that time he was compensated with options for EXACT Sciences stock. Sapna Syngal and Michael Lawson have collaborated with EXACT Sciences in previous studies. Neither one has been financially compensated by the company.
Accepted for publication June 8, 2004.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
D. A. Ahlquist, D. J. Sargent, C. L. Loprinzi, T. R. Levin, D. K. Rex, D. J. Ahnen, K. Knigge, M. P. Lance, L. J. Burgart, S. R. Hamilton, et al. Stool DNA and Occult Blood Testing for Screen Detection of Colorectal Neoplasia Ann Intern Med, October 7, 2008; 149(7): 441 - 450. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Levin, D. A. Lieberman, B. McFarland, R. A. Smith, D. Brooks, K. S. Andrews, C. Dash, F. M. Giardiello, S. Glick, T. R. Levin, et al. Screening and Surveillance for the Early Detection of Colorectal Cancer and Adenomatous Polyps, 2008: A Joint Guideline from the American Cancer Society, the US Multi-Society Task Force on Colorectal Cancer, and the American College of Radiology CA Cancer J Clin, May 1, 2008; 58(3): 130 - 160. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Zou, J. Harrington, R. L. Rego, and D. A. Ahlquist A Novel Method to Capture Methylated Human DNA from Stool: Implications for Colorectal Cancer Screening Clin. Chem., September 1, 2007; 53(9): 1646 - 1651. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Kann, J. Han, D. Ahlquist, T. Levin, D. Rex, D. Whitney, S. Markowitz, and A. Shuber Improved Marker Combination for Detection of De Novo Genetic Variation and Aberrant DNA in Colorectal Neoplasia Clin. Chem., December 1, 2006; 52(12): 2299 - 2302. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Levin Molecular Screening Testing for Colorectal Cancer Clin. Cancer Res., September 1, 2006; 12(17): 5014 - 5017. [Full Text] [PDF] |
||||
![]() |
W.-D. Chen, Z. J. Han, J. Skoletsky, J. Olson, J. Sah, L. Myeroff, P. Platzer, S. Lu, D. Dawson, J. Willis, et al. Detection in Fecal DNA of Colon Cancer-Specific Methylation of the Nonexpressed Vimentin Gene J Natl Cancer Inst, August 3, 2005; 97(15): 1124 - 1132. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. F. Imperiale, D. F. Ransohoff, S. H. Itzkowitz, B. A. Turnbull, M. E. Ross, and the Colorectal Cancer Study Group Fecal DNA versus Fecal Occult Blood for Colorectal-Cancer Screening in an Average-Risk Population N. Engl. J. Med., December 23, 2004; 351(26): 2704 - 2714. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |