From the Associated Regional and University Pathologists (ARUP) Institute for Clinical and Experimental Pathology,
*
Salt Lake City, Utah; the Department of Pathology,
University of Utah School of Medicine, Salt Lake City, Utah; Arcturus,
Mountain View, California; the Department of Pathology and Feist-Weiller Cancer Center,
Louisiana State University Health Sciences Center, Shreveport, Louisiana; and Sunnybrook and Womens College,
¶
Health Sciences Center, Toronto, Canada
| Abstract |
|---|
|
|
|---|
| Introduction |
|---|
|
|
|---|
Recent advances in polymerase chain reaction (PCR) technology using the real-time fluorescent monitoring capabilities of the LightCycler allow mutation detection and quantification of gene amplification.12 This technology combines real-time PCR and fluorescent detection using sequence-specific hybridization probes labeled with fluorophores. Fluorescent hybridization probes are designed to monitor product accumulation during the log phase of the PCR reaction13 and allow end-point analysis through the use of melting curves.14 We have developed two PCR assays with different levels of control, that quantify the HER2/neu gene amplification in DNA extracted from cell lines and from fresh-frozen and paraffin-embedded tissues. Both assays target the HER2/neu gene while using a single-copy gene, ß-globin, as an internal control. ß-globin was chosen as the reference gene because this area of chromosome 11p has not been shown to be commonly altered in breast cancer.15 Use of a non-chromosome 17 reference gene would detect increased HER2/neu copies due to gene amplification as well as to aneuploidy.16 HER2/neu and ß-globin are co-amplified in both assays and the HER2/neu gene copy number is normalized for ß-globin gene copy number. To control for run-to-run differences, a gene dose is obtained by adjusting the HER2/neu and ß-globin copy numbers with the MRC-5 cell line that carries a single copy of each gene.
In the first method, samples are amplified and quantified in real-time using external standard curves. HER2/neu and ß-globin gene copy numbers are obtained by comparing the second derivative maximum (crossing point) of sample curves with their respective standard curves.17
The second method uses competitive PCR for an additional level of control. Samples are co-amplified with a dilutional range of competitors that differ from the HER2/neu and ß-globin amplicons by one bp. Copy numbers for HER2/neu and ß-globin are determined by comparing the derivative melting curve area of target gene with the area of the competitor with known copy number.18 The target and competitor are differentiated based on melting temperature (Tm) of the probe. The Tm difference between the probe dissociating from a perfectly matched template and dissociating from a template with a single mismatch is 4 to 15°C, depending on the mismatch, the base composition of its nearest neighbors, length of the probe, and salt conditions.12 For this system, the Tm differences are 12°C for HER2/neu and 11°C for ß-globin.
The purpose of this study is to compare these two methods, examining correlation between the methods, the within- and between-run variation, the dynamic range and level of control necessary for precise analysis. On completion of the methods analysis, the real-time PCR method was chosen and accuracy of the method was determined against IHC staining.
| Materials and Methods |
|---|
|
|
|---|
DNA concentration was determined using the Pico-Green dsDNA Quantification kit (Molecular Probes, Eugene, OR) adapted to the LightCycler. The Lambda DNA standards were diluted twofold to give a concentration range from 200 ng/ml to 6.5 ng/ml. The reaction volume was reduced from 200 µl (manufacturers instructions) to 20 µl (10 µl sample + 10 µl dye) and loaded into LightCycler capillaries for both standards and unknowns. The fluorescence was read using the LightCycler fluorimeter after disabling the "Use Seek Threshold" option. The cycling program was set to hold the samples at 30°C while acquiring three fluorescence readings. Fluorescence was read in the 520-nm (fluorescein) channel. Fluorescent background was subtracted and a standard curve was generated by plotting fluorescence values against known standard concentrations. Unknown concentrations were determined by using the equation of the standard curve. DNA concentration of each of the three cell lines was determined to be 4 ng/µl (approximately 1200 copies of disomic genes/µl) using PicoGreen. A 1-µl volume of each cell line was used in the PCR.
DNA samples from fresh and frozen breast tumor tissues were obtained under a research protocol from Penrose Hospital (Colorado Springs, CO) and Louisiana State University Medical Center (Shreveport, LA). DNA concentrations were adjusted to 4 to 5 ng/µl in 10 mmol/L Tris (pH 8.0), containing 0.1 mmol/L EDTA. All samples were boiled for 10 minutes before PCR. DNA samples from paraffin-embedded tissues were obtained from Sunnybrook and Womens College, Health Sciences Center, Toronto, Canada.
Three hundred fifty-five paraffin-embedded breast tumor samples were obtained from ARUP (Salt Lake City, UT) under an Internal Review Board-approved protocol. Two 20-µm sections adjacent to the tissue used for the IHC staining were cut and one section was extracted using Puregene DNA Isolation Kit (Gentra, Minneapolis, MN). The other section was placed onto a glass slide to hold for possible microdissection. The monoclonal antibody c-erbB2/c-neu, clone 3B5, (Oncogene, CN Biosciences, Boston, MA) was used for the IHC staining. A subset of ten samples was prepared according to standard protocol (www.arctur.com) and microdissected using the Pixcell II Laser Capture Microdissection (LCM) system (Arcturus, Mountain View, CA). Approximately 100 nuclear targets were captured for each sample. DNA was isolated using the PicoPure DNA extraction kit (Arcturus).
Primers and Probes
Primer synthesis and labeling were performed as previously described.13, 23, 24
The forward primer for HER2/neu was 5'-CCT CTG ACG TCC ATC GTC TC-3'. The reverse primer for HER2/neu was 5'-CGG ATC TTC TGC TGC CGT CG-3'.18
The probe sequences were 5'-CTT GAT GAG GAT CCC AAA GAC CAC CCC CAA GAC CAC-3' with the 3' end labeled with fluorescein and 5'-ACC AGC AGA ATG CCA ACC A-3' with the 5' end labeled with LCRed 640 (Roche Molecular Biochemicals, Indianapolis, IN), and the 3' end blocked with a phosphate group.18
The primers for ß-globin were 5'-ACA CAA CTG TGT TCA CTA GC-3' (forward) and 5'-CAA CTT CAT CCA CGT TCA CC-3' reverse.25
The probe sequences for ß-globin were 5'-CCA CAG GGC AGT AAC GG-3' with the 3'end labeled with fluorescein and 5'-AGA CTT CTC CTC AGG AGT CAG GTG CAC CAT G-3' with the 5' end labeled with LCRed 705 (Roche Molecular Biochemicals, Indianapolis, IN), and the 3' end blocked with a phosphate group.
External Standards Preparation
External standards for HER2/neu and ß-globin were constructed by amplifying genomic DNA using rapid cycle PCR.12, 26
The PCRs were performed in two separate reactions using 0.5 µmol/L of each appropriate primer, 200 µmol/L each dNTP, 3.0 mmol/L MgCl2, 50 mmol/L Tris (pH 8.3), 500 mg/L bovine serum albumin, 0.4 U Taq polymerase (Boehringer Mannheim, Mannheim, Germany) and 250 ng DNA per 50 µl total reaction volume in a thin-walled microfuge tube adapted for use in a rapid air thermocycler (Rapid Cycler, Idaho Technology, Salt Lake City, UT). PCR conditions were 94°C for 30 seconds, 50°C for 30 seconds, and 75°C for 30 seconds for 30 cycles. The transition rate between 50°C and 75°C was 1.0°C/second.
PCR products (101 bp for HER2/neu and 110 bp for ß-globin) were visualized as single bands by agarose gel electrophoresis. PCR products were purified and concentrated using Amicon Ultrafree-DA (Millipore Corporation, Bedford, MA) membranes following manufacturers instructions. The amplicons were sequenced by dye-terminator chemistry (ABI 377 Sequencer, Applied Biosystems, Foster City, CA) for sequence confirmation. Concentrations were determined by PicoGreen as described above and converted to copy number. External standards of HER2/neu and ß-globin templates were combined in equal concentrations.
Internal Competitor Preparation
Internal competitors for HER2/neu and ß-globin were constructed in the same manner as the external standards except using an extended primer with a single base alteration from the wild-type sequence. The forward competitive primer for HER2/neu was 5'-CCT CTG ACG TCC ATC GTC TCT GCG GTG GTT [A]GC ATT CTG CTG GT-3'.14
The introduced base change is indicated in brackets. The reverse primer for ß-globin was modified with the sequence 5'-CAA CTT CAT CCA CGT TCA CCT TGC CCC ACA GGG [T]AG TAA CGG-3'.
LightCycler PCR Amplification
In both assays, the HER2/neu target sequence and a single-copy gene, ß-globin, were co-ampified in the same reaction. Five tenfold serially diluted external standards ranging from 1000,000 to 100 copies along with 4 ng of each unknown sample comprised the real-time PCR runs. The competitor PCR method used 4 ng of unknown sample co-amplified with five serial dilutions of competitor ranging from 25,000 to 1500 copies.
PCR for both methods was performed using 200 µmol/L each dNTP, 3.0 mmol/L MgCl2, 50 mmol/L Tris (pH 8.3), 500 mg/L bovine serum albumin, Klentaq polymerase (4 units/10 µl; AB Peptides, St. Louis, MO), and TaqStart antibody (0.32 µg/10 µl; Clontech, Palo Alto, CA). Primer concentrations were 0.5 µmol/L for the forward primer and 0.2 µmol/L for the reverse primer. Probe concentrations were 0.2 µmol/L. PCR conditions for the external standard method were 94°C for 3 seconds, 58°C for 10 seconds, and 75°C for 0 seconds for 40 cycles. The programmed transition rates were 20°C/second from denaturation to annealing, 1°C/second from annealing to extension (during which primer extension is occurring), and 20°C/second from extension to denaturation. Fluorescence was detected once per cycle at the end of the annealing stage. PCR conditions for the competitive PCR method were 94°C for 3 seconds, 53°C for 10 seconds, and 72°C for 0 seconds for 37 cycles. The programmed transition rates and detection of fluorescence were as described above. On completion of the amplification, the samples were denatured at 94°C for 3 seconds, cooled to 35°C at transition rate of 20°C/second, and held for 2 minutes. The samples were then heated to 90°C at a rate of 0.1°C/second with continuous fluorescence monitoring. The data were plotted as negative derivative fluorescent curves with respect to temperature (-dF/dT).
Analysis
Analysis was performed using two detection channels on the LightCycler. The LCRed640 channel was used to monitor the HER2/neu target and the LCRed705 channel was used to monitor the ß-globin target. A color compensation file was used to correct for fluorescence bleed-through.24
The real-time PCR method used crossing point analysis, the cycle number at which amplicon is first detectable, for quantification. The crossing points were obtained using the second derivative maximum (LightCycler 3 Data Analysis version 3.5.28 software). All calculations were made using the RealQuant software version 1.00 program (Roche Molecular Biochemicals, Indianapolis, IN).
The competitive PCR method used end-point analysis to compare competitor to target peak areas. Areas of the derivative melting curves were determined using non-linear least-squares regression analysis.14 The log of each target area/competitor area was plotted against the log of the competitor copy number. A line was fit through the plotted points, and the x axis intercept determined the target copy number.
For both methods, HER2/neu copy number was calculated as the ratio of HER2/neu copy number to ß-globin copy number. HER2/neu/ß-globin copy number was normalized between runs using the MRC-5 cell line to achieve a gene dose. A gene dose greater than 2.5 was considered amplified. Gene doses smaller than 1.5 were considered non-amplified, while gene doses between 1.5 and 2.5 were indeterminate.
| Results |
|---|
|
|
|---|
|
|
|
|
|
|
|
| Discussion |
|---|
|
|
|---|
Quantitative PCR must be accurate and precise to be implemented into a clinical laboratory. The added level of control using an internally amplified competitor may improve the precision of the assay. However, data acquisition by real-time analysis may eliminate the need for this extra level of control. We found that the within-run and between-run coefficients of variation (CVs) were comparable by both methods, indicating that both methods yield precise results.
The real-time assay has a higher throughput capacity. Results can be obtained on 24 samples per run, with four standards, two Her2/neu-positive controls (a low and a high level of amplification), a HER2/neu-negative control and a no template control included in each run. Competitive PCR is limited to five samples tested with four competitor dilutions per run. Positive and negative controls require three competitor dilutions flanking the equivalence point for each control. A no template control brings the number of capillaries necessary for controls to 10 per run.
The use of external standards provides a greater dynamic range than competitive PCR. The range covered by the real-time assay is over four logs. Any patient sample should fall within this range. With competitive PCR, samples are first run with up to four competitor concentrations. Depending on the sample:competitor ratio, the sample is re-run with adjusted competitor concentrations so that a linear curve fit can be obtained for analysis. The real-time assay requires less time for analysis, taking only 5 minutes when analyzing the samples using the RealQuant software. Analysis for the competitive PCR assay requires about 30 minutes.
Both assays were reproducible as demonstrated by low coefficients of variation in cell lines. The results from 97 DNAs extracted from fresh-frozen and paraffin samples correlated very well with a correlation coefficient of 0.974. Results correlated 100% when gene doses were scored as amplified (>2.5), negative (<1.5), or indeterminate (1.5 to 2.5). Samples in this indeterminate zone should undergo further testing by another method such as FISH or immunohistochemical staining.
Multiple methods are currently used to detect HER2/neu gene amplification. Tissue-based detection methods include FISH and immunohistochemical staining. These methods have the advantage of assessing the HER2/neu amplification in intact cells. However, both of these methods can be laborious for screening large numbers of samples. Real-time PCR has the advantage of automation and also allows levels of HER2/neu amplification to be easily evaluated. However, macro- or microdissection of tumor cells is necessary to eliminate dilution of apparent copy number by the non-tumor cells in the samples. Microdissection requires more technical time, about 10 minutes per section. A small sample size, about 100 cells, is adequate for amplification.
ß-globin was chosen as the reference gene because this area of chromosome 11 is under-represented is chromosomal abnormalities in breast cancer.15 Use of this reference gene would detect increased HER2/neu copies due to gene amplification as well as due to aneuploidy. Although chromosome 17 aneuploidy is not considered a major contributor to HER2/neu overexpression, recent studies have shown that increased HER2/neu protein expression has a higher correlation with absolute copies (signals/cell) of the Her2/neu gene in comparison to the HER2/neu gene to chromosome 17 ratio.16 A second reference gene on chromosome 17 could be added to our assay to address aneuploidy, and also make the PCR analysis more consistent with FISH methodologies that use chromosome 17 probes.
The focus of this investigation was to identify the level of control necessary in PCR analysis for potential use in the clinical laboratory. The comparison of real-time PCR with competitive PCR allowed us to demonstrate that the use of added controls for competitive PCR are not necessary. Using real-time PCR we can now continue to answer important questions about clinical sensitivity and specificity. These clinical studies, beyond the scope of this study, can be designed to address several issues. A study should be designed to compare PCR to FISH, using a chromosome 17 reference gene. Further validation should use micro- or macrodissected cells. In retrospect, we microdissected a small subset (10 of 57) of samples, demonstrating the necessity of microdissection. A larger study could answer the question to what extent will micro- or macrodissection hinder the rapid throughput potential of PCR. Evaluation of aneuploidy versus gene amplification as a mechanism of HER2/neu protein expression could be designed using a combination of a chromosome 17 and a non-chromosome 17 reference gene. Finally, a study could use real-time PCR to resolve discordance between FISH and IHC.
In view of all these observations, real-time PCR has potential for clinical use in HER2/neu quantification. The ease of use and broad dynamic range make it a viable screening tool for detection of HER2/neu amplification in fresh-frozen, paraffin-embedded, and microdissected samples.
| Acknowledgments |
|---|
| Footnotes |
|---|
Supported by the ARUP Institute for Clinical and Experimental Pathology and grant 99-3243 from the Susan G. Komen Breast Cancer Foundation.
Accepted for publication May 20, 2003.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
J. S. Ross, E. A. Slodkowska, W. F. Symmans, L. Pusztai, P. M. Ravdin, and G. N. Hortobagyi The HER-2 Receptor and Breast Cancer: Ten Years of Targeted Anti-HER-2 Therapy and Personalized Medicine Oncologist, April 1, 2009; 14(4): 320 - 368. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. A. Iverson, C. Gillett, P. Cane, C. D. Santini, T. M. Vess, L. Kam-Morgan, A. Wang, M. Eisenberg, C. M. Rowland, J. J. Hessling, et al. A Single-Tube Quantitative Assay for mRNA Levels of Hormonal and Growth Factor Receptors in Breast Cancer Specimens J. Mol. Diagn., March 1, 2009; 11(2): 117 - 130. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Lyon and C. T. Wittwer LightCycler Technology in Molecular Diagnostics J. Mol. Diagn., March 1, 2009; 11(2): 93 - 101. [Abstract] [Full Text] [PDF] |
||||
![]() |
C.-H. Yeh, W. A. Whitmire III, and M. Albitar Liquid-Based Fluorescence In Situ Hybridization Assay for Detection of ERBB2 Gene Amplification in Patients with Breast Cancer Clin. Chem., November 1, 2008; 54(11): 1831 - 1839. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Katsumi, Y. Kuwahara, S. Tamura, K. Kikuchi, O. Otabe, K. Tsuchiya, T. Iehara, H. Kuroda, H. Hosoi, and T. Sugimoto Trastuzumab Activates Allogeneic or Autologous Antibody-Dependent Cellular Cytotoxicity against Malignant Rhabdoid Tumor Cells and Interleukin-2 Augments the Cytotoxicity Clin. Cancer Res., February 15, 2008; 14(4): 1192 - 1199. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. McCabe, M. Dolled-Filhart, R. L. Camp, and D. L. Rimm Automated Quantitative Analysis (AQUA) of In Situ Protein Expression, Antibody Concentration, and Prognosis J Natl Cancer Inst, December 21, 2005; 97(24): 1808 - 1815. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |