JMD Conference & Exhibition
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Originally published online as doi:10.2353/jmoldx.2007.060134 on August 9, 2007

Published online before print August 9, 2007
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
jmoldx.2007.060134v1
9/4/421    most recent
Right arrow Purchase Article
Right arrow View Shopping Cart
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zhang, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zhang, T.
Journal of Molecular Diagnostics 2007, Vol. 9, No. 4
Copyright © 2007 American Society for Investigative Pathology & Association for Molecular Pathology
DOI: 10.2353/jmoldx.2007.060134


Special Article

Inter-Laboratory Comparison of Chronic Myeloid Leukemia Minimal Residual Disease Monitoring

Summary and Recommendations

Tong Zhang*, Sylvie Grenier*, Bevoline Nwachukwu*, Cuihong Wei*{dagger}, Jeffrey H. Lipton{ddagger}, Suzanne Kamel-Reid*{dagger}{ddagger} the Association for Molecular Pathology Hematopathology Subdivision

From the Department of Pathology, * Molecular Diagnostics, and the Department of Medicine, {ddagger} Princess Margaret Hospital, The University Health Network, Toronto, Ontario; and the Department of Laboratory Medicine and Pathobiology, {dagger} University of Toronto, Toronto, Ontario, Canada

In patients with chronic myeloid leukemia, the use of real-time quantitative reverse transcription-polymerase chain reaction (qRT-PCR) for measuring BCR-ABL1 transcripts has become standard methodology for the diagnosis and monitoring of minimal residual disease. In 2004 and 2005, 38 different laboratories from North America participated in three separate sample exchanges using real-time qRT-PCR to measure RNA transcript levels in unknown diluents of a BCR-ABL1-positive cell line, K562. In this study we compared results of quantitative testing for BCR-ABL1 from laboratories using different platforms, internal controls, reagents, and calculation methods. Our data showed that there can be considerable variability of results from laboratory to laboratory, with log reduction calculations varying from 1.6 to 3 log between laboratories at the same dilution. We found that none of the variables tested had a significant impact on the results reported, except for the use of ABL1 as the internal control (P < 0.001). Laboratories that used ABL1 consistently underreported their log reduction values. Regardless of the specific methodology and platform used for real-time qRT-PCR testing, it is important for laboratories to participate in proficiency testing to ensure consistent and acceptable test accuracy and sensitivity. Our study emphasizes the need for optimization of real-time qRT-PCR before offering clinical testing and the need for widely available universal standards that can be used for test calibration.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the American Society for Investigative Pathology and the Association for Molecular Pathology.