| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
From the Research Center for Genetic Medicine, Childrens National Medical Center, Washington, District of Columbia
Rett syndrome is a neurodevelopmental disorder that affects females almost exclusively, and in which eight common point mutations on the X-linked MeCP2 gene are knows to cause over 70% of mutation-positive cases. We explored the use of a novel platform to detect the eight common mutations in Rett syndrome patients to expedite and simplify the process of identification of known genotypes. The Nanogen workstation consists of a two-color assay based on electric hybridization and thermal discrimination, all performed on an electronically active NanoChip. This genotyping platform was tested on 362 samples of a pre-determined genotype, which had been previously identified by a combination of DHPLC (denaturing high performance liquid chromatography) and direct sequencing. This genotyping technique proved to be rapid, facile, and displayed a specificity of 100% with 3% ambiguity. In addition, we present consecutive testing of seven mutations on a single pad of the NanoChip. This was accomplished by tagging down two amplimers together and serially hybridizing for seven different loci, allowing us to genotype samples for seven of the eight common Rett mutations on a single pad. This novel method displayed the same level of specificity and accuracy as the single amplimer reactions, and proved to be faster and more economical.
This article has been cited by other articles:
![]() |
P. Huppke and J. Gartner Molecular Diagnosis of Rett Syndrome J Child Neurol, September 1, 2005; 20(9): 732 - 736. [Abstract] [PDF] |
||||
![]() |
P. Huppke and J. Gartner Molecular Diagnosis of Rett Syndrome J Child Neurol, August 1, 2005; 20(8): 732 - 736. [Abstract] [PDF] |
||||
![]() |
N. A. Saunders, S. Alexander, and I. Tatt env Gene Typing of Human Immunodeficiency Virus Type 1 Strains on Electronic Microarrays J. Clin. Microbiol., April 1, 2005; 43(4): 1910 - 1916. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Frusconi, B. Giusti, L. Rossi, S. Bernabini, F. Poggi, I. Giotti, R. Abbate, G. Pepe, and F. Torricelli Improvement of Low-Density Microelectronic Array Technology to Characterize 14 Mutations/Single-Nucleotide Polymorphisms from Several Human Genes on a Large Scale Clin. Chem., April 1, 2004; 50(4): 775 - 777. [Full Text] [PDF] |
||||
![]() |
A. A. Sethi, A. Tybjaerg-Hansen, R. V. Andersen, and B. G. Nordestgaard Nanogen Microelectronic Chip for Large-Scale Genotyping Clin. Chem., February 1, 2004; 50(2): 443 - 446. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |