JMD ASIP MEMBERSHIP
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ogino, S.
Right arrow Articles by Wilson, R. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ogino, S.
Right arrow Articles by Wilson, R. B.
JMD 2002, Vol. 4, No. 4
Copyright © 2002 American Society for Investigative Pathology & Association for Molecular Pathology

Quantification of PCR Bias Caused by a Single Nucleotide Polymorphism in SMN Gene Dosage Analysis

Shuji Ogino*{dagger}{ddagger} and Robert B. Wilson§

From the Department of Pathology, * Brigham and Women’s Hospital, Boston; the Department of Medical Oncology, {dagger} Dana-Farber Cancer Institute, Boston; Harvard Medical School, {ddagger} Boston, Massachusetts; and the Department of Pathology and Laboratory Medicine, § University of Pennsylvania Medical Center, Philadelphia, Pennsylvania

Approximately 94% of patients with spinal muscular atrophy lack both copies of SMN1 exon 7, and most carriers have only one copy of SMN1 exon 7. We described previously the effect of SMN1/SMN2 heteroduplex formation on SMN gene dosage analysis, which is a multiplex quantitative PCR assay to determine the copy numbers of SMN1 and SMN2 using DraI digestion to differentiate SMN2 from SMN1. We describe herein the quantification of PCR bias between SMN1 exon 7 and SMN2 exon 7, which differ by only one nucleotide that is not present in either primer binding site. Using samples from 272 individuals with various SMN genotypes, we found that the amplification efficiency of SMN2 was consistent only approximately 80% that of SMN1. Thus, even a single nucleotide polymorphism, not in primer binding sites, can cause reproducible PCR bias. The precision and accuracy of our SMN gene dosage analysis are high because our assay design and controls take advantage of the consistency of the PCR bias. As additional clinically significant single nucleotide polymorphisms (SNPs) are discovered, assessment of PCR bias, and judicious selection of standards and controls, will be increasingly important for quantitative PCR assays.




This article has been cited by other articles:


Home page
J. Mol. Diagn.Home page
S. Ogino, T. Kawasaki, M. Brahmandam, M. Cantor, G. J. Kirkner, D. Spiegelman, G. M. Makrigiorgos, D. J. Weisenberger, P. W. Laird, M. Loda, et al.
Precision and Performance Characteristics of Bisulfite Conversion and Real-Time PCR (MethyLight) for Quantitative DNA Methylation Analysis
J. Mol. Diagn., May 1, 2006; 8(2): 209 - 217.
[Abstract] [Full Text] [PDF]


Home page
J. Mol. Diagn.Home page
S. Ogino, T. Kawasaki, M. Brahmandam, L. Yan, M. Cantor, C. Namgyal, M. Mino-Kenudson, G. Y. Lauwers, M. Loda, and C. S. Fuchs
Sensitive Sequencing Method for KRAS Mutation Detection by Pyrosequencing
J. Mol. Diagn., August 1, 2005; 7(3): 413 - 421.
[Abstract] [Full Text] [PDF]


Home page
Nucleic Acids ResHome page
J. H. Watterson, S. Raha, C. C. Kotoris, C. C. Wust, F. Gharabaghi, S. C. Jantzi, N. K. Haynes, N. H. Gendron, U. J. Krull, A. E. Mackenzie, et al.
Rapid detection of single nucleotide polymorphisms associated with spinal muscular atrophy by use of a reusable fibre-optic biosensor
Nucleic Acids Res., January 23, 2004; 32(2): e18 - e18.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the American Society for Investigative Pathology and the Association for Molecular Pathology.