JMD Conference & Exhibition
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kleiber, J.
Right arrow Articles by Rosenstraus, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kleiber, J.
Right arrow Articles by Rosenstraus, M.
JMD 2000, Vol. 2, No. 3
Copyright © 2000 American Society for Investigative Pathology & Association for Molecular Pathology

Performance Characteristics of a Quantitative, Homogeneous TaqMan RT-PCR Test for HCV RNA

Joerg Kleiber, Thomas Walter, Gerd Haberhausen, Sue Tsang, Reiner Babiel and Maurice Rosenstraus

From Roche Molecular Systems, Inc., Pleasanton, California

We developed a homogeneous format reverse transcription-polymerase chain reaction assay for quantitating hepatitis C virus (HCV) RNA based on the TaqMan principle, in which signal is generated by cleaving a target-specific probe during amplification. The test uses two probes, one specific for HCV and one specific for an internal control, containing fluorophores with different emission spectra. Titers are calculated in international units (IU)/ml by comparing the HCV signal generated by test samples to that generated by a set of external standards. Endpoint titration experiments demonstrated that samples containing 28 IU/ml give positive results 95% of the time. Based on these data, the limit of detection was set conservatively at 40 IU/ml. All HCV genotypes were amplified with equal efficiency and accurately quantitated: when equal quantities of RNA were tested, each genotype produced virtually identical fluorescent signals. The test exhibited a linear range extending from 64 to 4,180,000 IU/ml and excellent reproducibility, with coefficients of variation ranging from 21.6 to 30.4%, which implies that titers that differ by a factor of twofold (0.3 log10) are statistically significant (P = 0.005). The test did not react with other organisms likely to co-infect patients with hepatitis C and exhibited a specificity of 99% when evaluated on a set of samples from HCV seronegative blood donors. In interferon-treated patients, the patterns of viral load changes revealed by the TaqMan HCV quantitative test distinguished responders from nonresponders and responder-relapsers. These data indicate that the TaqMan quantitative HCV test provides an attractive alternative for measuring HCV viral load and should prove useful for prognosis and for monitoring the efficacy of antiviral treatments.




This article has been cited by other articles:


Home page
Antimicrob. Agents Chemother.Home page
P. Huang, D. A. Goff, Q. Huang, A. Martinez, X. Xu, S. Crowder, S. D. Issakani, E. Anderson, N. Sheng, P. Achacoso, et al.
Discovery and Characterization of Substituted Diphenyl Heterocyclic Compounds as Potent and Selective Inhibitors of Hepatitis C Virus Replication
Antimicrob. Agents Chemother., April 1, 2008; 52(4): 1419 - 1429.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
M. F. Sabato, M. L. Shiffman, M. R. Langley, D. S. Wilkinson, and A. Ferreira-Gonzalez
Comparison of Performance Characteristics of Three Real-Time Reverse Transcription-PCR Test Systems for Detection and Quantification of Hepatitis C Virus
J. Clin. Microbiol., August 1, 2007; 45(8): 2529 - 2536.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
P. Laurent, K. Le Roux, P. Grivard, G. Bertil, F. Naze, M. Picard, F. Staikowsky, G. Barau, I. Schuffenecker, and A. Michault
Development of a Sensitive Real-Time Reverse Transcriptase PCR Assay with an Internal Control to Detect and Quantify Chikungunya Virus
Clin. Chem., August 1, 2007; 53(8): 1408 - 1414.
[Abstract] [Full Text] [PDF]


Home page
J. Virol.Home page
J. Bartolome, J. M. Lopez-Alcorocho, I. Castillo, E. Rodriguez-Inigo, J. A. Quiroga, R. Palacios, and V. Carreno
Ultracentrifugation of Serum Samples Allows Detection of Hepatitis C Virus RNA in Patients with Occult Hepatitis C
J. Virol., July 15, 2007; 81(14): 7710 - 7715.
[Abstract] [Full Text] [PDF]


Home page
Clin. Microbiol. Rev.Home page
M. J. Espy, J. R. Uhl, L. M. Sloan, S. P. Buckwalter, M. F. Jones, E. A. Vetter, J. D. C. Yao, N. L. Wengenack, J. E. Rosenblatt, F. R. Cockerill III, et al.
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Clin. Microbiol. Rev., January 1, 2006; 19(1): 165 - 256.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
J. J. Germer, W. S. Harmsen, J. N. Mandrekar, P. S. Mitchell, and J. D. C. Yao
Evaluation of the COBAS TaqMan HCV Test with Automated Sample Processing Using the MagNA Pure LC Instrument
J. Clin. Microbiol., January 1, 2005; 43(1): 293 - 298.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
L. Cook, K.-W. Ng, A. Bagabag, L. Corey, and K. R. Jerome
Use of the MagNA Pure LC Automated Nucleic Acid Extraction System followed by Real-Time Reverse Transcription-PCR for Ultrasensitive Quantitation of Hepatitis C Virus RNA
J. Clin. Microbiol., September 1, 2004; 42(9): 4130 - 4136.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
J. M. Barbeau, J. Goforth, A. M. Caliendo, and F. S. Nolte
Performance Characteristics of a Quantitative TaqMan Hepatitis C Virus RNA Analyte-Specific Reagent
J. Clin. Microbiol., August 1, 2004; 42(8): 3739 - 3746.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
J. J. Germer, M. M. Lins, M. E. Jensen, W. S. Harmsen, D. M. Ilstrup, P. S. Mitchell, F. R. Cockerill III, and R. Patel
Evaluation of the MagNA Pure LC Instrument for Extraction of Hepatitis C Virus RNA for the COBAS AMPLICOR Hepatitis C Virus Test, Version 2.0
J. Clin. Microbiol., August 1, 2003; 41(8): 3503 - 3508.
[Abstract] [Full Text] [PDF]


Home page
Appl. Environ. Microbiol.Home page
M. M. Brinig, P. W. Lepp, C. C. Ouverney, G. C. Armitage, and D. A. Relman
Prevalence of Bacteria of Division TM7 in Human Subgingival Plaque and Their Association with Disease
Appl. Envir. Microbiol., March 1, 2003; 69(3): 1687 - 1694.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
R. Ovstebo, K. B. F. Haug, K. Lande, and P. Kierulf
PCR-based Calibration Curves for Studies of Quantitative Gene Expression in Human Monocytes: Development and Evaluation
Clin. Chem., March 1, 2003; 49(3): 425 - 432.
[Abstract] [Full Text] [PDF]


Home page
Nucleic Acids ResHome page
I. M. Mackay, K. E. Arden, and A. Nitsche
Real-time PCR in virology
Nucleic Acids Res., March 15, 2002; 30(6): 1292 - 1305.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
W. A. Verstrepen, S. Kuhn, M. M. Kockx, M. E. Van De Vyvere, and A. H. Mertens
Rapid Detection of Enterovirus RNA in Cerebrospinal Fluid Specimens with a Novel Single-Tube Real-Time Reverse Transcription-PCR Assay
J. Clin. Microbiol., November 1, 2001; 39(11): 4093 - 4096.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Society for Investigative Pathology and the Association for Molecular Pathology.